Home/Compliance & Safety
Back to Home
Zero-Harm Culture & Regulatory Rigor

Compliance, EHS & Safety Framework

Standard operating protocols, Central Electricity Authority (CEA) safety guidelines, Karnataka State Pollution Control Board (KSPCB) effluent standards, and Contract Labour regulations observed across all client facilities.

1. High-Voltage & Electrical Safety Engineering

Electrical safety is our primary engineering mandate. High-voltage operations involving 11kV/33kV substations, HT VCB breakers, LT ACB panels, and oil-immersed transformers strictly comply with:

Central Electricity Authority (CEA) Regulations, 2010Strict adherence to safety and electric supply clearances, earthing continuity, and certified substation insulation levels.
Lockout / Tagout (LOTO) ProceduresMandatory dual-key isolation and tag application before servicing any busduct, breaker chamber, or capacitor bank.
NFPA 70E & IEEE 1584 Arc Flash StandardsArc-flash hazard assessments and calibrated arc-rated protective clothing worn during live panel inspections.
Indian Standards (IS 3043 & IS 732)Quarterly earth pit resistance testing ensuring soil resistance remains below 1.0 Ohm across neutral and body earthing grids.

2. Environmental & KSPCB Regulatory Compliance

Our turnkey Sewage Treatment Plant (STP) and Water Treatment Plant (WTP) operations adhere strictly to KSPCB consent-to-operate (CTO) criteria and Central Pollution Control Board (CPCB) benchmarks:

Water Quality ParameterKSPCB Permissible Limit96K Ventures Quality Standard
pH Level6.5 – 8.57.0 – 7.8 (Stable Neutral)
Biochemical Oxygen Demand (BOD)< 10 mg/L< 5 mg/L (High Purity)
Chemical Oxygen Demand (COD)< 50 mg/L< 30 mg/L (Advanced Oxidation)
Total Suspended Solids (TSS)< 10 mg/L< 5 mg/L (Dual Media Filtered)
Fecal Coliform< 100 MPN / 100 mlNil / Non-Detectable (Ozonated / UV)

* Hazardous sludge and contaminated transformer oil are disposed of strictly via KSPCB-authorized re-processors in compliance with the Hazardous Wastes Management Rules, 2016.

3. Statutory Labour Governance & Workforce Welfare

We maintain 100% compliance with all Indian labor welfare legislation. Our deployed technical staff, licensed electricians, STP operators, and facility crews are covered under:

Employees' Provident Fund (EPF)

Monthly statutory EPF contributions deposited via Electronic Challan cum Return (ECR) with zero default history.

Employees' State Insurance (ESIC)

Comprehensive medical and hospital coverage for all technicians and their families under the ESI Act, 1948.

Karnataka Minimum Wages Act

Strict compliance with scheduled employment minimum wage rates, overtime allowances, and statutory bonus disbursements.

Contract Labour Act, 1970

Valid contractor licenses, certified muster rolls, and periodic wage register audits submitted to client HR desks.

4. Personal Protective Equipment (PPE) Matrix

Zero compromises on PPE. Our technical specialists are equipped with certified personal protective gear according to job hazard analysis:

Electrical Technicians

Class 4 (36kV) Rubber Gloves, Arc-Flash 40 cal/cm² Suits, Dielectric Safety Boots, Face Visors.

STP/WTP Operators

Chemical-resistant Nitrile Gloves, Full-face Gas Respirators, Non-slip Acid-proof Gumboots, Splash Aprons.

Maintenance Crews

EN397 Industrial Helmets, High-Visibility Class 2 Vests, Steel-Toe Safety Footwear, Fall-Arrest Harnesses.

5. Fire Safety & Emergency Escalation Protocol

We maintain a 24/7 Breakdown & Emergency Incident Response Desk for all managed infrastructure in Bengaluru:

Emergency Escalation Timeline (< 30 Minutes Trigger)

In the event of an unscheduled breaker trip, transformer overheating, pump failure, or water flooding, our 24/7 emergency dispatch helpline triggers mobile engineering dispatch within 30 minutes of call logging.

Emergency Hotline: +91 83173 84461•Dispatch Email: 96kventures@gmail.com

Third-Party Audits & Calibration Transparency

All measurement instruments (FLIR thermal imaging cameras, relay test kits, BDV test cells, earth resistance meters) undergo annual NABL calibration. All client testing certificates and logbook summaries are submitted digitally every month.

Audited Entity: 96K VENTURESHeadquarters: Bengaluru, Karnataka